Notes d’application

Ti2: Increasing data collection and fidelity by maximizing field of view

septembre 2019


A1R HD25: the latest in resonant scanning technology allows new live-cell imaging approaches

février 2019

Capturing the dynamics of living systems requires high acquisition rates. Large samples, such as whole model organisms, additionally require a large field of view. The Nikon A1R HD25 confocal system provides both, combining Nikon’s improved HD high speed resonant scanner with an unprecedented 25 mm field of view. The performance of this system is evaluated in zebrafish embryos.


Increasing Data Collection and Fidelity by Maximizing Confocal Field of View

novembre 2018

For years, the field of view (FOV) of confocal systems has been limited by the FOV of the microscope they are attached to. With the release of the Nikon Ti2 inverted microscope, the world’s first 25-mm FOV became available. Now, Nikon has taken advantage of this improvement by building the largest FOV point scanner in the world, the A1 HD25. This Application Note focuses on the impact of this technology on simple, everyday experiments.


Structured Illumination Microscopy (SIM) Imaging Comparison with Confocal

septembre 2018

The super-resolution microscopy technique structured illumination microscopy (SIM) imaging of dendritic spines along the dendrite has not been previously performed in fixed tissues, mainly due to deterioration of the stripe pattern of the excitation laser induced by light scattering and optical aberrations.


Reflectance imaging for visualization of unlabeled structures using Nikon A1 and N-SIM

janvier 2018

Reflectance imaging allows the user to form an intensity image from light backscattered by the sample. Highly reflective markers, including a variety of nanoparticles, allows for imaging with very high signal-to-noise and virtually free of photobleaching, ideal for both confocal and structured illumination microscopies.


Hardware Triggering: Maximizing Speed and Efficiency for Live Cell Imaging

décembre 2017

Live cell imaging experiments now require higher speeds and more data throughput than ever before. Nikon Instruments has robust tools that enable hardware triggering of imaging devices in microscopy via direct signaling between hardware. This minimizes delays, synchronizes devices, and reduces the exposure of specimens to light. This Application Note explains how Nikon’s NIS-Elements hardwaretriggering workflow operates, and details its benefits for common time-lapse acquisition routines.


Application of Patterned Illumination Using a DMD for Optogenetic Control of Signaling

novembre 2017

Digital micromirror devices (DMDs) are powerful tools for photostimulation applications, including photoconversion and optogenetic manipulation, owing to their robust ability to produce novel illumination patterns with high spatiotemporal resolution. In this Application Note we showcase recent work describing how DMD technology integrated into a Nikon system can be applied toward light-gated optogenetic control of intracellular signaling.


Robotic Microscopy with the Nikon Ti2 for High-Content Analysis Applications

décembre 2016

Robotic Microscopy—a combination of high-content screening methods—enables multivariate experimental approaches with large cell populations and member-level sensitivity. Here we explore how the new Nikon Ti2 line of inverted research microscopes is uniquely suited to Robotic Microscopy applications, focusing on work utilizing induced pluripotent stem cells (iPSCs) as disease models in drug screening.


N-STORM with DNA-PAINT for Reliable Multicolor & 3D Single Molecule Localization Imaging

novembre 2016


N-SIM for Quantitative Ultra-Structural Analyses of the Nuclear Lamina

octobre 2016

Super-resolution Structured Illumination Microscopy (SIM), available from Nikon via the N-SIM and N-SIM E systems, allows for the observation of details inaccessible to traditional microscopes, such as confocal and widefield. In this application note we see how the N-SIM system enables quantitative multi-color evaluation of the distribution of different nuclear lamin proteins and the structures they form.


Quantitative Cluster Analysis Applications for N-STORM

octobre 2016

Nikon’s N-STORM super-resolution microscope is applied to mapping the distribution of nucleosomes on chromatin fibers, shining a light on the mechanisms of chromatin folding, gene expression, and pluripotency. Multicolor STORM is used to explore how nucleosome distribution differs between differentiated and pluripotent stem cells and correlates with the distribution of other important factors in replication, such as RNA Polymerase II.


Nikon’s Large-Format Multiphoton System for Intravital Imaging

décembre 2015

Nikon’s A1R MP multiphoton confocal microscope system provides a choice platform for deep tissue imaging. Researchers at the Allen Institute for Brain Science have applied the A1R MP towards fast dual-color intravital imaging of the mouse brain. The open architecture instrument design allows for the addition of custom stages for large samples, external photostimulation devices, and more – perfect for constantly evolving needs.


Quantitative Analysis Tools and Correlative Imaging Applications for N-STORM

novembre 2015

Stochastic Optical Reconstruction Microscopy (STORM) has had a significant impact on our understanding of nano-scale biological processes. In this application note, we see how Nikon’s N-STORM system, combined with quantitative analysis tools, enables single molecule level studies of cannabinoid signaling in the brain. Correlative 3D-STORM, confocal microscopy, and patch-clamp electrophysiology is also explored.


Stem Cell Research with Nikon

mai 2014

This flyer provides a quick visual orientation of example Nikon products and how they support various research aspects of stem cell biology and regenerative medicine. This includes detection of differentiation markers, routine cell culture checking, time lapse imaging, and more.


Development of an Integrated Bioprocess for Production of NK-92 Cells for Immunotherapy

janvier 2014

Anti-cancer NK-92 lymphocytes are promising for application in immunotherapies. This application note explores a comprehensive workflow for producing clinical-grade NK-92 cells, using Nikon’s BioStation CT to monitor NK-92 phenotype and potency.


Antitumor Lymphocyte Kinetic Cytotoxicity Assay (Collaboration with CCRM)

janvier 2013

In this application note we explore the use of the fully robotic Nikon BioStation CT high content screening microscope platform towards quantifying the death rate of a model human leukemia cell line upon co-incubation with anticancer NK-92 lymphocytes. This assay integrates automated imaging of Calcein-AM fluorescence to perform live/dead cell analysis.


A Non-Invasive Method for Counting Human Pluripotent Stem Cell Numbers by Live Cell Imaging

janvier 2012

Presented here is a method for counting live pluripotent stem cells using the fluorescent nuclear stain SYTO24 and phase contrast imaging on the Nikon BioStation CT high content screening microscope. The results show that colony coverage area deduced from phase contrast images can be used as an accurate estimator of stem cell count alone, correlating well with haemocytometer-based measurements.


Outline of Stem Cell Applications

janvier 2011

The Nikon BioStation CT cell culture observation system and CL-Quant software provide a powerful platform for stem cell research applications, including automated induced pluripotent stem (iPS) cell colony identification, proliferation analysis, and neural differentiation analysis. Real experimental data is provided for each of these use cases.


Screening Assay for PSC Responses to Substrates

janvier 2011

An automated imaging-based screening assay for assessing stem cell pluripotency is described. Researchers from Nikon and the Centre for Commercialization of Regenerative Medicine use a Nikon BioStation CT with CL-Quant software to perform stem cell pluripotency maintenance assays in experiments testing feeder cell-free culture vessel substrates. Such commercially available substrates provide a number of process standardization benefits.


Automated Haematopoietic Colony Forming Cell (CFC) Assay

janvier 2011

Nikon’s BioStation CT high content live cell screening system is applied in an assay for automated enumeration and identification of haematopoietic colony-forming cells. This assay allows for the identification of multiple colony types, helping distinguish between lineages.


Generation of a Growth Curve for iPS Cells in a Feeder-Free Culture by Non-Invasive Image Analysis

janvier 2011

Long-term time-lapse observation of feeder layer-free stem cell cultures, along with automated detection of stem cell colonies, is demonstrated here using a Nikon BioStation CT system. Growth curves for both differentiated and un-differentiated cells were generated for a time period of about 1 week.


Establishment of an Algorithm for Automated Detection of iPS/non-iPS Cells Under a Culture Condition by Non-Invasive Image Analysis

janvier 2011

In this application note we detail an automated high throughput method for observing and classifying stem cell colonies with a standardized algorithm and using the Nikon BioStation CT. Automated image analysis discriminates stem cell colonies from non-stem cell colonies using phase contrast imaging and subsequent analysis of distinguishing morphological features.


Automated, Non-Invasive Culture, and Evaluation System for iPS Cells under Neural Differentiation Process

janvier 2011

This application note details an integrated workflow for the culture, observation, evaluation, and differentiation of induced pluripotent stem (iPS) cells into neurons, introducing image processing methods for detecting neural rosettes and neurite outgrowth – two important morphological checkpoints in neural differentiation. Automated imaging for this assay is performed using a Nikon BioStation CT.


Embryonic Stem Cell Responses to Commercially Available Substrates for Stem Cell Maintenance

janvier 2011

In collaboration with the Centre for Commercialization of Regenerative Medicine (CCRM) we compare the performance of 8 common substrates for stem cell growth and maintenance by developing an assay utilizing the Nikon BioStation CT high content screening microscope and incubation system. Fluorescence imaging of Oct4 is used as a marker for pluripotency.


Survival Analysis of Human In Vitro-derived Neurons Using New Live Cell Extended Time-lapse Imaging Technology

janvier 2011

In this application note we demonstrate the Nikon BioStation CT for long-term live-cell imaging of stem cell-derived motor neurons – tracking key attributes such as cell body size and neurite length before, during, and after treatment with different stressors. This approach provides a standardized method for drug discovery studies in neurodegenerative disease models.